Microneedles With Interdigitated Electrodes for in Situ Impedimetric Vegf Sensing

dc.authoridDAS, RITU/0000-0003-3783-9160
dc.authorscopusid58262247800
dc.authorscopusid57200181969
dc.authorscopusid57204273303
dc.authorscopusid58267172300
dc.authorscopusid59508940200
dc.authorscopusid55322124400
dc.authorscopusid24066881900
dc.authorwosidIstif, Emin/JGM-0202-2023
dc.authorwosidBeker, Levent/AAX-3281-2020
dc.authorwosidDas, Ritu/M-9564-2019
dc.contributor.authorDas, Ritu
dc.contributor.authorIstif, Emin
dc.contributor.authorCebecioglu, Rumeysa
dc.contributor.authorAli, Mohsin
dc.contributor.authorAtik, Yasin
dc.contributor.authorDag, Cagdas
dc.contributor.authorBeker, Levent
dc.date.accessioned2025-02-15T19:38:24Z
dc.date.available2025-02-15T19:38:24Z
dc.date.issued2025
dc.departmentKadir Has Universityen_US
dc.department-temp[Das, Ritu; Istif, Emin; Atik, Yasin; Beker, Levent] Koc Univ, Dept Mech Engn, TR-34450 Istanbul, Turkiye; [Istif, Emin] Kadir Has Univ, Fac Engn & Nat Sci, Dept Mol Biol & Genet, TR-34083 Istanbul, Turkiye; [Cebecioglu, Rumeysa; Ali, Mohsin; Beker, Levent] Koc Univ, Dept Biomed Sci & Engn, TR-34450 Istanbul, Turkiye; [Dag, Cagdas; Beker, Levent] Koc Univ, Nanofabricat & Nanocharacterizat Ctr Sci & Technol, TR-34450 Istanbul, Turkiye; [Celikbas, Eda; Demirci, Gozde; Acar, Fundayagci] Koc Univ, Dept Chem, TR-34450 Istanbul, Turkiye; [Hasanreisoglu, Murat] Koc Univ Hosp, Sch Med, Dept Opthalmol, TR-34010 Istanbul, Turkiyeen_US
dc.descriptionDAS, RITU/0000-0003-3783-9160en_US
dc.description.abstractContinuous monitoring of protein biomarkers in interstitial fluid (ISF) is essential for improving patient care and outcomes. This study presents a novel electrochemical impedance spectroscopy (EIS) sensor utilizing microneedles (MNs) patterned with interdigitated electrodes for the detection of vascular endothelial growth factor (VEGF). The MNs, are fabricated from flexible polylactide (PLA) using a simple molding technique, followed by metal deposition with an interdigitated pattern to serve as a platform for the EIS sensor. After functionalization with anti-VEGF antibodies, impedance measurements are conducted to detect VEGF levels, demonstrating a significant change in impedance in response to varying concentrations of the target biomarker. The MNs can easily penetrate rat skin by hand, puncturing without mechanical breakage. This innovative approach enhances the sensitivity and specificity of biomarker detection and paves the way for continuous monitoring applications in diagnostics and preventative medicine.en_US
dc.description.sponsorshipTUBITAK 2232 [118C295]; European Research Council [101043119]; European Research Council (ERC) [101043119] Funding Source: European Research Council (ERC)en_US
dc.description.sponsorshipL.B. acknowledges TUBITAK 2232 (grant no. 118C295) and the European Research Council (2ND-CHANCE, grant no. 101043119). The authors acknowledge Koc University Surface Science and Technology Center (KUYTAM) and Koc University Nanofabrication and Nanocharacterization Center (n2STAR) for access to the infrastructure.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.citation0
dc.identifier.doi10.1002/admi.202400789
dc.identifier.issn2196-7350
dc.identifier.scopus2-s2.0-85214699710
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1002/admi.202400789
dc.identifier.urihttps://hdl.handle.net/20.500.12469/7172
dc.identifier.wosWOS:001391831700001
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiosensoren_US
dc.subjectCapacitiveen_US
dc.subjectMicroneedleen_US
dc.subjectVegfen_US
dc.titleMicroneedles With Interdigitated Electrodes for in Situ Impedimetric Vegf Sensingen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files