Microneedles With Interdigitated Electrodes for in Situ Impedimetric Vegf Sensing
dc.authorid | DAS, RITU/0000-0003-3783-9160 | |
dc.authorscopusid | 58262247800 | |
dc.authorscopusid | 57200181969 | |
dc.authorscopusid | 57204273303 | |
dc.authorscopusid | 58267172300 | |
dc.authorscopusid | 59508940200 | |
dc.authorscopusid | 55322124400 | |
dc.authorscopusid | 24066881900 | |
dc.authorwosid | Istif, Emin/JGM-0202-2023 | |
dc.authorwosid | Beker, Levent/AAX-3281-2020 | |
dc.authorwosid | Das, Ritu/M-9564-2019 | |
dc.contributor.author | Das, Ritu | |
dc.contributor.author | Istif, Emin | |
dc.contributor.author | Cebecioglu, Rumeysa | |
dc.contributor.author | Ali, Mohsin | |
dc.contributor.author | Atik, Yasin | |
dc.contributor.author | Dag, Cagdas | |
dc.contributor.author | Beker, Levent | |
dc.date.accessioned | 2025-02-15T19:38:24Z | |
dc.date.available | 2025-02-15T19:38:24Z | |
dc.date.issued | 2025 | |
dc.department | Kadir Has University | en_US |
dc.department-temp | [Das, Ritu; Istif, Emin; Atik, Yasin; Beker, Levent] Koc Univ, Dept Mech Engn, TR-34450 Istanbul, Turkiye; [Istif, Emin] Kadir Has Univ, Fac Engn & Nat Sci, Dept Mol Biol & Genet, TR-34083 Istanbul, Turkiye; [Cebecioglu, Rumeysa; Ali, Mohsin; Beker, Levent] Koc Univ, Dept Biomed Sci & Engn, TR-34450 Istanbul, Turkiye; [Dag, Cagdas; Beker, Levent] Koc Univ, Nanofabricat & Nanocharacterizat Ctr Sci & Technol, TR-34450 Istanbul, Turkiye; [Celikbas, Eda; Demirci, Gozde; Acar, Fundayagci] Koc Univ, Dept Chem, TR-34450 Istanbul, Turkiye; [Hasanreisoglu, Murat] Koc Univ Hosp, Sch Med, Dept Opthalmol, TR-34010 Istanbul, Turkiye | en_US |
dc.description | DAS, RITU/0000-0003-3783-9160 | en_US |
dc.description.abstract | Continuous monitoring of protein biomarkers in interstitial fluid (ISF) is essential for improving patient care and outcomes. This study presents a novel electrochemical impedance spectroscopy (EIS) sensor utilizing microneedles (MNs) patterned with interdigitated electrodes for the detection of vascular endothelial growth factor (VEGF). The MNs, are fabricated from flexible polylactide (PLA) using a simple molding technique, followed by metal deposition with an interdigitated pattern to serve as a platform for the EIS sensor. After functionalization with anti-VEGF antibodies, impedance measurements are conducted to detect VEGF levels, demonstrating a significant change in impedance in response to varying concentrations of the target biomarker. The MNs can easily penetrate rat skin by hand, puncturing without mechanical breakage. This innovative approach enhances the sensitivity and specificity of biomarker detection and paves the way for continuous monitoring applications in diagnostics and preventative medicine. | en_US |
dc.description.sponsorship | TUBITAK 2232 [118C295]; European Research Council [101043119]; European Research Council (ERC) [101043119] Funding Source: European Research Council (ERC) | en_US |
dc.description.sponsorship | L.B. acknowledges TUBITAK 2232 (grant no. 118C295) and the European Research Council (2ND-CHANCE, grant no. 101043119). The authors acknowledge Koc University Surface Science and Technology Center (KUYTAM) and Koc University Nanofabrication and Nanocharacterization Center (n2STAR) for access to the infrastructure. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.citation | 0 | |
dc.identifier.doi | 10.1002/admi.202400789 | |
dc.identifier.issn | 2196-7350 | |
dc.identifier.scopus | 2-s2.0-85214699710 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.uri | https://doi.org/10.1002/admi.202400789 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12469/7172 | |
dc.identifier.wos | WOS:001391831700001 | |
dc.identifier.wosquality | Q2 | |
dc.language.iso | en | en_US |
dc.publisher | Wiley | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Biosensor | en_US |
dc.subject | Capacitive | en_US |
dc.subject | Microneedle | en_US |
dc.subject | Vegf | en_US |
dc.title | Microneedles With Interdigitated Electrodes for in Situ Impedimetric Vegf Sensing | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |