Electro-Pneumatic Assessment of Airflow in a Double-Piston Cylinder Ventilator

dc.authorscopusid 58000882000
dc.authorscopusid 58075874100
dc.authorscopusid 58660904600
dc.authorscopusid 59311078100
dc.authorscopusid 59911463700
dc.authorscopusid 58574305400
dc.contributor.author Oyejide, A.J.
dc.contributor.author Atoyebi, E.O.
dc.contributor.author Ugo, H.C.
dc.contributor.author Chukwudi, F.O.
dc.contributor.author Akindel, G.
dc.contributor.author Adeyemi, A.A.
dc.date.accessioned 2025-06-15T21:48:51Z
dc.date.available 2025-06-15T21:48:51Z
dc.date.issued 2024
dc.department Kadir Has University en_US
dc.department-temp [Oyejide A.J.] Afe Babalola University, Department of Biomedical Engineering, Ado Ekiti, Nigeria; [Atoyebi E.O.] Federal University of Technology, Department of Biomedical Technology, Akure, Nigeria; [Ugo H.C.] Afe Babalola University, Department of Biomedical Engineering, Ado Ekiti, Nigeria; [Chukwudi F.O.] Afe Babalola University, Department of Biomedical Engineering, Ado Ekiti, Nigeria; [Akindel G.] Kadir Has University, Department of Electronics Engineering, Istanbul, Turkey; [Adeyemi A.A.] Kadir Has University, Dept. Computational Science and Engineering, Istanbul, Turkey en_US
dc.description.abstract Mechanical ventilation is crucial for patients with severe respiratory distress. While single piston-actuated ventilation is popular, this study presents an electro-pneumatic assessment of airflow in a coupled-double-acting piston ventilator (DPDACV) using simulation results from FluidSIM. The DPDACV design aims to leverage a dual-piston mechanism for enhanced stability and performance in tidal volume delivery. Simulations conducted over 2, 10, 30, and 60 seconds revealed that the DPDACV provides more consistent volume delivery, stable flow rates, and relatively higher, more stable pressure levels compared to single-piston systems. These findings suggest that the DPDACV can offer improved ventilation efficiency and patient safety, contributing valuable insights to the field of mechanical ventilation. © 2024 IEEE. en_US
dc.identifier.doi 10.1109/NIGERCON62786.2024.10927314
dc.identifier.issn 2377-2689
dc.identifier.issue 2024 en_US
dc.identifier.scopus 2-s2.0-105005940115
dc.identifier.scopusquality N/A
dc.identifier.uri https://doi.org/10.1109/NIGERCON62786.2024.10927314
dc.identifier.uri https://hdl.handle.net/20.500.12469/7363
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Institute of Electrical and Electronics Engineers Inc. en_US
dc.relation.ispartof IEEE International Conference on Emerging and Sustainable Technologies for Power and ICT in a Developing Society, NIGERCON -- 5th IEEE International Conference on Electro-Computing Technologies for Humanity, NIGERCON 2024 -- 26 November 2024 through 28 November 2024 -- Ado Ekiti -- 207826 en_US
dc.relation.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 0
dc.subject Covid-19 en_US
dc.subject Fluidsim en_US
dc.subject Medical Device en_US
dc.subject Piston Ventilator en_US
dc.subject Respiration en_US
dc.title Electro-Pneumatic Assessment of Airflow in a Double-Piston Cylinder Ventilator en_US
dc.type Conference Object en_US
dspace.entity.type Publication

Files