Design and Implementation of a 10 Kv/10 Kw High-Frequency Center-Tapped Transformer

dc.contributor.author Rahman, Showrov
dc.contributor.author Candan, Muhammed Yusuf
dc.contributor.author Tamyurek, Bunyamin
dc.contributor.author Aydin, Emrullah
dc.contributor.author Mese, Huseyin
dc.contributor.author Aydemir, M. Timur
dc.contributor.other Electrical-Electronics Engineering
dc.contributor.other 05. Faculty of Engineering and Natural Sciences
dc.contributor.other 01. Kadir Has University
dc.date.accessioned 2023-10-19T15:12:35Z
dc.date.available 2023-10-19T15:12:35Z
dc.date.issued 2022
dc.description.abstract High voltage high-frequency (HVHF) transformers have a crucial part in the realization of high voltage direct current (HVDC) isolated power supplies. Nevertheless, they are the bulkiest component in the system besides being one of the major contributors to the power losses. Special care is therefore required to design HVHF transformers. The main objective of this paper is to design and implement a high voltage (10 kV), high-frequency (50 kHz) center-tapped transformer with high efficiency, small size, and low cost. The proposed transformer is designed as part of a 100 kV, 10 kW DC/DC converter for supplying power to a particle accelerator. The proposed transformer steps up the input voltage (500 V) to 10 kV. Then, a five-stage full-wave Cockcroft-Walton voltage multiplier (CWVM) is used for boosting the voltage to 100 kV. A detailed step-by-step design guideline for designing an HVHF transformer is also presented. To reduce the transformer's parasitic capacitance, the secondary windings are wrapped in segments. This taken approach has been illustrated in the paper and later verified through finite element analysis (FEA). The FEA analysis shows that the transformer parasitic capacitance has reduced significantly. Following the presented design guideline, the implemented prototype transformer has been built and later tested with a single-stage CWVM. The experimental results demonstrate that the prototype transformer has successfully met the design requirements including the small size, less weight, and low-cost objectives. en_US
dc.description.sponsorship ASELSANInc. Turkey; ASELSAN Inc. en_US
dc.description.sponsorship This researchworkwas funded byASELSANInc. Turkey, and the authors would like to thank ASELSAN Inc. for providing technical and financial support. en_US
dc.identifier.citationcount 1
dc.identifier.doi 10.1007/s00202-022-01499-3 en_US
dc.identifier.issn 0948-7921
dc.identifier.issn 1432-0487
dc.identifier.scopus 2-s2.0-85124460632 en_US
dc.identifier.uri https://doi.org/10.1007/s00202-022-01499-3
dc.identifier.uri https://hdl.handle.net/20.500.12469/5484
dc.khas 20231019-WoS en_US
dc.language.iso en en_US
dc.publisher Springer en_US
dc.relation.ispartof Electrical Engineering en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject High-Voltage
dc.subject Cockcroft-Walton voltage multiplier en_US
dc.subject High voltage direct current power supply en_US
dc.subject High-Voltage En_Us
dc.subject High voltage high-frequency transformer en_US
dc.subject Converters
dc.subject Segmented winding en_US
dc.subject Converters En_Us
dc.subject Transformer parasitics en_US
dc.title Design and Implementation of a 10 Kv/10 Kw High-Frequency Center-Tapped Transformer en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Rahman, Showrov/0000-0003-1447-236X
gdc.author.id AYDIN, EMRULLAH/0000-0003-0086-8611
gdc.author.id CANDAN, MUHAMMED YUSUF/0000-0002-2164-6543
gdc.author.id Tamyurek, Bunyamin/0000-0002-0034-3754
gdc.author.institutional Aydemir, Mehmet Timur
gdc.author.wosid Rahman, Showrov/HZL-3988-2023
gdc.author.wosid AYDIN, EMRULLAH/ACL-9254-2022
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.departmenttemp [Rahman, Showrov; Tamyurek, Bunyamin] Gazi Univ, Dept Elect & Elect Engn, Ankara, Turkey; [Candan, Muhammed Yusuf] ASELSAN INC, Ankara, Turkey; [Aydin, Emrullah] Malatya Turgut Ozal Univ, Dept Elect & Elect Engn, Malatya, Turkey; [Mese, Huseyin] TOGG INC, Ankara, Turkey; [Aydemir, M. Timur] Kadir Has Univ, Dept Elect & Elect Engn, Istanbul, Turkey en_US
gdc.description.endpage 2619 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q2
gdc.description.startpage 2603 en_US
gdc.description.volume 104 en_US
gdc.identifier.openalex W4210885178
gdc.identifier.wos WOS:000753250900003 en_US
gdc.oaire.diamondjournal false
gdc.oaire.impulse 3.0
gdc.oaire.influence 2.8490101E-9
gdc.oaire.isgreen false
gdc.oaire.keywords Cockcroft-Walton voltage multiplier
gdc.oaire.keywords High-Voltage
gdc.oaire.keywords Segmented winding
gdc.oaire.keywords Converters
gdc.oaire.keywords Transformer parasitics
gdc.oaire.keywords High voltage direct current power supply
gdc.oaire.keywords High voltage high-frequency transformer
gdc.oaire.popularity 4.091478E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.fwci 0.181
gdc.openalex.normalizedpercentile 0.49
gdc.opencitations.count 2
gdc.plumx.mendeley 2
gdc.plumx.scopuscites 3
gdc.scopus.citedcount 3
gdc.wos.citedcount 2
relation.isAuthorOfPublication 3970d2e9-726a-42ce-96b5-7040860161dc
relation.isAuthorOfPublication.latestForDiscovery 3970d2e9-726a-42ce-96b5-7040860161dc
relation.isOrgUnitOfPublication 12b0068e-33e6-48db-b92a-a213070c3a8d
relation.isOrgUnitOfPublication 2457b9b3-3a3f-4c17-8674-7f874f030d96
relation.isOrgUnitOfPublication b20623fc-1264-4244-9847-a4729ca7508c
relation.isOrgUnitOfPublication.latestForDiscovery 12b0068e-33e6-48db-b92a-a213070c3a8d

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
5484.pdf
Size:
3.62 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text