Critical Phenomenon During Photoinitiated Gelation at Different Temperatures: a Photo-Dsc Study

dc.contributor.author Dogruyol, Zekeriya
dc.contributor.author Pekcan, Mehmet Önder
dc.contributor.author Arsu, Nergis
dc.contributor.author Dogruyol, Sevnur Keskin
dc.contributor.author Pekcan, Önder
dc.contributor.other Molecular Biology and Genetics
dc.date.accessioned 2019-06-27T08:04:35Z
dc.date.available 2019-06-27T08:04:35Z
dc.date.issued 2011
dc.department Fakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Biyoinformatik ve Genetik Bölümü en_US
dc.description.abstract The behaviour of photoinitiated radical polymerization of an 80 wt% epoxy diacrylate (EA) and 20 wt% tripropyleneglycoldiacrylate (TPGDA) mixture with 2-mercaptothioxanthone (TX-SH) photoinitiator was studied at different temperatures by using photo-differential scanning calorimetric (Photo-DSC) technique. All photopolymerization reactions were carried out under the same conditions. It was observed that all conversion curves during gelation at different temperatures present nice sigmoidal behaviour which suggests the application of the percolation model. Observations around the critical time called the glass transition point (t(g)) taken to reach the maximum rate of polymerization (Rp(max)) show that the gel fraction exponent (beta) obeyed the percolation model. The produced beta values were found to be around 0.50 predicting that the system under consideration belongs to the same universality class. However. Rp(max) and the final conversion (C(s)) values were found to increase when the temperature was increased up to a certain value. On the other hand t(g) values decreased and became saturated as the temperature was increased. (C) 2011 Elsevier B.V. All rights reserved. en_US]
dc.identifier.citationcount 6
dc.identifier.doi 10.1016/j.porgcoat.2011.08.008 en_US
dc.identifier.endpage 768
dc.identifier.issn 0300-9440 en_US
dc.identifier.issn 0300-9440
dc.identifier.issue 4
dc.identifier.scopus 2-s2.0-80054940943 en_US
dc.identifier.scopusquality Q1
dc.identifier.startpage 763 en_US
dc.identifier.uri https://hdl.handle.net/20.500.12469/961
dc.identifier.uri https://doi.org/10.1016/j.porgcoat.2011.08.008
dc.identifier.volume 72 en_US
dc.identifier.wos WOS:000297454900021 en_US
dc.identifier.wosquality Q1
dc.institutionauthor Pekcan, Önder en_US
dc.language.iso en en_US
dc.publisher Elsevier Science en_US
dc.relation.journal Progress in Organic Coatings en_US
dc.relation.publicationcategory Diğer en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 8
dc.subject Percolation en_US
dc.subject Temperature en_US
dc.subject Epoxy acrylate en_US
dc.subject Photo-DSC en_US
dc.subject Critical exponent en_US
dc.title Critical Phenomenon During Photoinitiated Gelation at Different Temperatures: a Photo-Dsc Study en_US
dc.type Review en_US
dc.wos.citedbyCount 6
dspace.entity.type Publication
relation.isAuthorOfPublication e5459272-ce6e-44cf-a186-293850946f24
relation.isAuthorOfPublication.latestForDiscovery e5459272-ce6e-44cf-a186-293850946f24
relation.isOrgUnitOfPublication 71ce8622-7449-4a6a-8fad-44d881416546
relation.isOrgUnitOfPublication.latestForDiscovery 71ce8622-7449-4a6a-8fad-44d881416546

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Critical phenomenon during photoinitiated gelation at different temperatures A Photo-DSC study.pdf
Size:
707.01 KB
Format:
Adobe Portable Document Format
Description: