Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers

dc.authoridAkcelyan, Sarven/0000-0001-5811-5546
dc.contributor.authorAkcelyan, Sarven
dc.contributor.authorLignos, Dimitrios G.
dc.date.accessioned2023-10-19T15:12:03Z
dc.date.available2023-10-19T15:12:03Z
dc.date.issued2023
dc.department-temp[Akcelyan, Sarven] Kadir Has Univ, Dept Civil Engn, TR-34083 Istanbul, Turkiye; [Lignos, Dimitrios G.] Ecole Polytech Fed Lausanne EPFL, Civil Engn Inst, EPFL, ENAC,IIC,RESSLab, GC B3 485,Stn 18, CH-1015 Lausanne, Switzerlanden_US
dc.description.abstractThis paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous seismic performance assessment based on ASCE 41 recommendations reveals a high collapse risk for the existing building. The local engineering demand parameters are comprehensively assessed to quantify the impact of seismic retrofit on steel columns and column splices, which are particularly vulnerable due to the time of construction. Multiple retrofit schemes are explored with numerous damping levels and vertical damping distribution methods. The dampers are designed via a recently developed multi-degree-of-freedom performance curves method. A new balanced vertical damping method is proposed to account for the effects of frame inelasticity. This strongly depends on the supplemental damping level, and it determines the effectiveness of the employed vertical damping distribution method. The results indicate that the proposed retrofit strategies can minimize the collapse risk of the tall building. It is shown that the balanced vertical damping distribution method provides the most uniform drift distribution along the building height. Despite the reduction in story drift ratios, the axial force demand in exterior columns remains relatively high in the bottom stories regardless of the seismic retrofit solution. On the other hand, bilinear oil dampers produce relative constant forces despite exhibiting higher velocity demands than expected.en_US
dc.description.sponsorshipFonds de recherche du Quebec Nature et technologies [2013-NC-166845]; Natural Sciences and Engineering Research Council of Canada (NSERC); Ecole Polytechnique Federale de Lausanne (EPFL); Individual Research Fund of Kadir Has Universityen_US
dc.description.sponsorshipThis research was supported by Fonds de recherche du Quebec Nature et technologies (Grant No. 2013-NC-166845), Natural Sciences and Engineering Research Council of Canada (NSERC), Individual Research Fund of Kadir Has University, and internal funding from Ecole Polytechnique Federale de Lausanne (EPFL). The findings in this paper are those of the authors and do not necessarily reflect the view of the sponsors.en_US
dc.identifier.citation1
dc.identifier.doi10.3390/buildings13010139en_US
dc.identifier.issn2075-5309
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85146652705en_US
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.3390/buildings13010139
dc.identifier.urihttps://hdl.handle.net/20.500.12469/5327
dc.identifier.volume13en_US
dc.identifier.wosWOS:000917056700001en_US
dc.identifier.wosqualityN/A
dc.institutionauthorAkçelyan, Sarven
dc.khas20231019-WoSen_US
dc.language.isoenen_US
dc.publisherMdpien_US
dc.relation.ispartofBuildingsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectViscous DampersEn_Us
dc.subjectPerformanceEn_Us
dc.subjectDesignEn_Us
dc.subjectProtectionEn_Us
dc.subjectSplicesEn_Us
dc.subjectModelsEn_Us
dc.subjectViscous Dampers
dc.subjectsupplemental dampingen_US
dc.subjectPerformance
dc.subjectbilinear oil dampersen_US
dc.subjectDesign
dc.subjectseismic retrofiten_US
dc.subjectProtection
dc.subjectcollapse risken_US
dc.subjectSplices
dc.subjectperformance-based designen_US
dc.subjectModels
dc.subjecttall buildingsen_US
dc.titleSeismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampersen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication1ac5e890-5b0d-44f0-95eb-da46a947e398
relation.isAuthorOfPublication.latestForDiscovery1ac5e890-5b0d-44f0-95eb-da46a947e398

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
5327.pdf
Size:
1.24 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text