Use of octopus 2 stabilization system for off-pump coronary artery bypass grafting

dc.contributor.authorGüden, M
dc.contributor.authorAkpmar, B
dc.contributor.authorSagbas, E
dc.contributor.authorSanisoglu, I
dc.contributor.authorAytekin, V
dc.contributor.authorBayindir, O
dc.date.accessioned2024-10-15T19:41:09Z
dc.date.available2024-10-15T19:41:09Z
dc.date.issued2000
dc.departmentKadir Has Universityen_US
dc.department-tempKadir Has Univ, Fac Med, Florence Nightingale Hosp, Dept Cardiovasc Surg, Istanbul, Turkeyen_US
dc.description.abstractThe early results of 126 off pump CABG procedures performed through a median sternotomy incision (OPCAB) during a period of 18 months were evaluated. The mean age was 69+/-4.3 years. There were 80 male and 46 female patients. Emergency cases and reoperations were not included. A total of 268 anatomosis were performed with a mean number of 2.12 anastomosis Per patient. Conduits used were: LITA (100%), RITA (11.1%) GSV in (84%) and radial artery in (31%) of cases. In 72% of the cases, off pump surgery was chosen because of patient risk factors such as atherosclerotic aortic disease, previous CVA or carotid artery disease, renal dysfunction, malignancy and poor LV function. There was no operative mortality. One month mortality was 3 patients (2.3%). Two died because of mesentheric ischemia. 71 patients had a control angiogram before discharge. The patency of LITA anastomosis was 100% while overall patency rate was 95%. In 43 patients were an angiogram could not be performed, a Thalium 201 stress test was performed 3 months postoperatively. 38 had a normal test while 5 patients showed signs of ischemia. These patients had a control angiogram, in four patients anastomosis were patent, but in one patient tere was a severe narrowing of a venous anastomosis to the distal right coronary which was corrected with angioplasty. In the whole series 8 patients refused to have any control examination (6.3%). Our early results suggest that off pump CABG with Octopus stabilisation can be a good alternative in high risk patients who need multiple vessel revascularisation.en_US
dc.description.woscitationindexConference Proceedings Citation Index - Science
dc.identifier.citation0
dc.identifier.doi[WOS-DOI-BELIRLENECEK-24]
dc.identifier.endpage139en_US
dc.identifier.isbn8832306247
dc.identifier.scopusqualityN/A
dc.identifier.startpage131en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12469/6412
dc.identifier.wosWOS:000089220500021
dc.identifier.wosqualityN/A
dc.language.isoenen_US
dc.publisherMedimond S R Len_US
dc.relation.ispartof49th International Congress of the European-Society-for-Cardiovascular-Surgery -- JUN 24-27, 2000 -- Dresden, GERMANYen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[No Keyword Available]en_US
dc.titleUse of octopus 2 stabilization system for off-pump coronary artery bypass graftingen_US
dc.typeConference Objecten_US
dspace.entity.typePublication

Files