TR-Dizin İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12469/4467
Browse
Browsing TR-Dizin İndeksli Yayınlar Koleksiyonu by browse.metadata.publisher "AVES YAYINCILIK"
Now showing 1 - 6 of 6
- Results Per Page
- Sort Options
Article Broadband Matching Via Reflection Coefficient Modeling(AVES YAYINCILIK, 2016) Şengül, Metin Y.[Abstract Not Available]Article Design of Low-Pass Ladder Networks With Mixed Lumped and Distributed Elements by Means of Artificial Neural Networks(AVES YAYINCILIK, 2003) Şengül, Metin Y.; Özmen, Atilla; Yılmaz, MelekIn this paper, calculation of parameters of low-pass ladder networks with mixed lumped and distributed elements by means of artificial neural networks is given. The results of ANN are compared with the values that are desired. It has been observed that the calculated and the desired values are extremely close to each other. So this algorith can be used to obtain the parameters that will be used to synthesize such circuits.Article Hücresel Sinir Ağları için Gerilim Kaynaklı Hücre Modelleri(AVES YAYINCILIK, 2001) Tander, Baran; Ün, MahmutBu makalede, bağımsız ve bağımlı gerilim kaynağı tabanlı yeni bir Hücresel Sinir Ağı hücre devresi önerilmiştir. Bu modelde akım kaynaklı Chua ve Yang ‘ın klasik hücre devresinin aksine hücreler için denge noktaları dinamik birimdeki Rx ve Cx’ den bağımsızdırlar. Tam bir hücre devresi tasarlanıp kararlı ve kararsız durumlar için benzetimleri yapılmıstır. Önerilen modelin avantaj ve dezavantajları sonuçlar bölümünde tartışılmıştır.Other Simple and Accurate Cell Macromodels for the Simulations of Cellular Neural Networks(AVES YAYINCILIK, 2002) Tander, Baran; Ün, MahmutIn this paper, two simple and accurate cell macromodels for PSPICE simulations of Cellular Neural Networks (CNNs) are designed. Firstly, a brief information about CNNs and their benefits are introduced. Then the nonlinear differential equations that characterize the CNNs and the equivalent cell circuit given by Chua and Yang which realizes these equations are presented. With appropriate source transformations, another cell equivalent that employs voltage controlled-voltage sources instead of voltage controlled-current sources is developed. By substituting the dependent sources with their actual circuits for both equivalents, complete systems which are suitable for PSPICE macromodeling are derived. Responses of astable and stable CNNs are analyzed with the proposed macromodels and satisfactory results are observed after the simulations. The benefits and drawbacks of the macromodels are also discussed in the conclusion section.Article Synthesis of Lossless Ladder Networks With Simple Lumped Elements Connected Via Commensurate Transmission Lines(AVES YAYINCILIK, 2010) Şengül, Metin Y.An algorithm has been proposed, to synthesize low-pass, high-pass, band-pass and band-stop lossless ladder networks with simple lumped elements connected via commensurate transmission lines (Unit elements, UEs). First, the type of the element that will be extracted is determined from the given mixed-element network function. After obtaining element value, it is extracted, and the two-variable reflection function of the remaining mixed-element network is obtained. This process is repeated until extracting all the elements. For each network type, an example is included, to illustrate the implementation of the related algorithm.Other Uykusuzluk Süresince ve Sonrasında Opsonizasyon(AVES YAYINCILIK, 2002) Öztürk, Levent; Sağlam, İbrahim Yaman; Gökhan, NuranBu çalışmada, 48 saat uykusuzluğun, fagositik aktiviteyi belirleyen göstergelerden biri olan opsonizasyon üzerine etkileri araştırıldı. Sağlıklı, genç erişkin 10 erkek gönüllü çalışmaya dahil edildi. Fizik muayene sonrasında, denekler, uyku bozukluğu açısından değerlendirilmek amacıyla bir gece poligrafik uyku kayıdına alındılar. Uyku tetkikini takiben 48 saat süre ile sedanter koşullarda uykusuz bırakılan denekler, yine kayıt altında telafi uykularını uyudular. 0 -24 - 48 ve 72. saatlerde venöz kan örnekleri toplandı. Alınan kan örneklerinde kortizol, IgG ve klasik protokole uygun olarak opsonizasyon değerlendirildi. Sonuçlarımıza göre, 48 saat uykusuzluğun, sağlıklı insanlarda opsonizasyonda anlamlı bir değişikliğe neden olmadığı saptandı.